TM 10-5410-229-13&P1-10.LOCATION AND DESCRIPTION OF MAJOR PARTS - Cont’d.(1)PlainWallLiner. The plain wall liner (1) is constructed of a lightweight, pajama check weave cloth and isapproximately 12’ wide x 7 high. On the inside, eight quick release male fasteners are located approximately 18" apartalong the top edge. Seven buckle assemblies with quick release female fasteners are located approximately 12" apartand 22" from the edge along each side, with three more located approximately 5’apart and 12" above the bottom edge. Anidentification label is sewn to the inside. In addition, seven side straps with quick release male fasteners are locatedapproximately 12" apart along the outer edge of each side. On the outside, a 2" strip of pile fastener is sewn along theupper seam of the liner. The plain wall liner provides insulation and can be used as outside wall in hot weather duringdaylight hours. The liner also assists in providing light discipline. One plain wall liner is issued with each MCPS.(2)PlainWall. The plain wall (2) is constructed of mildew and flame resistant polyester duck cloth and isapproximately 12’6" wide x 8’ high. On the inside, eight quick release male fasteners are located approximately 18" apartalong the top edge. Four female quick release fasteners are also located along the top, spaced about 40" apart. Sevenbuckle assemblies with quick release female fasteners are located approximately 12" apart and 22" from the edge alongeach side, with three more approximately 5’ apart and 24" above the bottom edge. A 2" wide hook fastener strip is locatedalong the top, the upper corners, and the outer edge of the right side. An identification label is sewn to the inside of thewall. On the outside, four roll up straps are located approximately 40" apart along the top and seven small buckleassemblies with quick release female fasteners are located approximately 12" apart and 22" from the edge along the rightside. In addition, seven side straps with quick release male fasteners are located about 12" apart along the outer edge ofeach side. A 2" wide pile fastener strip is located along the top, the upper corners, and the fold line of the right side. Oneplain wall is issued with each MCPS.(3)WindowWall. The window wall (3) is constructed similar to the plain wall except that it contains a 38" x 38"clear plastic window, a nylon webbing screen, and a window flap. The screen is sewn into the window opening. Thewindow is sewn to the bottom seam of the window opening and 1" wide pile fastener strips are located around its outeredges. A 1" wide hook fastener strip is located around the inside seams of the window opening. On the outside, a windowflap with 1" wide pile fastener strips along its inside edge is sewn to the upper window seam.1-5
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business