WARNING

DO NOT OPEN THE AMMONIA CHEST WHILE THE MACHINE IS RUNNING. Be sure that all ammonia has drained from the machine. Stand back from the machine when the chest is open. There is a heavy charge of ammonia in the chamber. Be sure to provide ventilation at all times when the ammonia chest is open. When removing jammed paper from the ammonia chest, do not bend or scratch any of the mechanical parts in the chest.

Because of described qualities of the aqueous ammonia, it is important that a NITE-SHEET be run in the developer section when the machine is not in operation for a period of time (nights, weekends, etc.). This nite-sheet can be a wide sheet of sensitized paper long enough to extend from both the entrance and exit of the developer section. Stop the machine when this is accom-plished, allowing the sheet to remain. This sheet will absorb the excess vapor and condensation, leaving a dry chamber when the machine is started again.

MAINTENANCE. Periodic maintenance and inspection of the Blu-Ray machine are essential. Major maintenance and repairs should be performed only by skilled service personnel. For maximum light exposure, it is very important that the exterior and interior of the glass cylinder be cleaned frequently. When the glass cylinder needs to be cleaned, follow the steps given below.

1. Disconnect the electrical cord from its power source.

2. Remove both end panels from the machine by removing the panel-holding screws.

3. Back off the locking screw and open the drive-section cover.

4. Disconnect the lamp cartridge wiring. DO NOT PULL THE WIRES; grasp the plug.

5. Unfasten the lamp cartridge by removing the screws at the right-hand end of the lamp cartridge frame. Gently remove the lamp cartridge, ensuring that the wires at the left-hand end of the cartridge do not snag.

6. Thoroughly clean the glass-printing cylinder and lamps. Use the manufacturers recommended glass cleaner or an ammonia-water solution. NEVER use an abrasive cleaner on the glass cylinder.

It is inherent in the nature of fluorescent lamps to lose brilliancy after months of usage. This requires the machine to be slowed down to produce the desired prints. When this occurs, the lamps should be replaced, Since the lamp cartridge must be removed when the glass-printing cylinder interior is being cleaned, burned out or weak lamps should be replaced at the same time. Lamps, as well as any other parts needed, should be obtained through your supply system. It is recommended that the lamp starters be replaced when the lamps are being replaced. The lamp starters are located in the ballast panel in the back of the machine. For ease of removal and replacement, a portion of the ballast panel cover must be removed to expose the starters.

Printer feed belts may become slack over a period of time, causing slippage and blurred prints. A simple adjustment may be made as follows:

1. Pull the small Tygon tube out of the ammonia supply bottle cap.

2. Run the machine until the tube is pumped dry and no longer feeding the ammonia tank in the machine.

3. Raise the motor end of the machine a few inches for a moment for complete drainage.

4. Shut off the machine.

5. Tip the machine on its back carefully so the ammonia tubes and power cord that project from the back will not be crushed or kinked. This will expose the two slotted idler take-up brackets.

6. Loosen the two screws in both brackets, and press down approximately one-fourth in, beyond the previous setting to give proper tension to the belts, and re-secure. Make sure that both brackets are set at the same position.

The components in the ammonia chest are readily accessible and easily removed. The top cover is removed by sliding a door-catch type of pivot and then lifting it off of the machine. The back chest panel can be removed independently for internal inspection by removing four screws and sliding the panel out of the machine. Both the upper and lower paper combs are attached to the back chest panel, allowing for inspection and replacement of their combs when the panel is removed. Take out the ammonia tank first. The ammonia tank is independently removed from the ammonia chest by removing the two wing screws on the right-hand end of the machine where the tank drains. Disconnect the Tygon ammonia in-feed tube in the motor end of the machine, and slide the tank out to the right. The grid and drive roll assemblies are easily removed as a unit by unscrewing the plastic drive-roll plug at the right end of the drive roll. Slide the drive roll off of a pin slot connector to the drive shaft, and lift the assembly up and out of the chest.

After 600 hr of operation, the plastic Tygon tube in the ammonia pump will need to be replaced. Extra tubing is supplied with the machine for this purpose. To replace a tube, remove the left-hand end panel by removing the screws holding down the drive-section top cover. This will expose the pump with its motor and all the tube connections. Study how the tube is placed so that after it is removed you can place the new tube properly.

There is a tube coupling on the tube support bracket. Pull the tube lead to the pump from the coupling.

Jog the machine by snapping the power switch ON and OFF. The old tube will move out of the pump by normal rotating pump action. Pull this tube off of the ammonia feed pipe leading into the machine.

Take a piece of replacement tubing and cut the end on a bias (slant) so it will feed through the pump smoothly. Feed the tubing into the coupling end of the pump and jog the machine (as before) so the tube will be pulled through the pump.

When this tube is completely in the pump, cut it to length and reattach as before to the ammonia coupling and ammonia feed pipe.

The upper faceplate and the developer feed plate extrusions are removed by removing two screws from each and lifting them off of the machine. This will expose the lower slider gasket. The lower slider gasket is attached to the gasket retainer angle and is removed as a unit by removing the fastening screws. A replacement gasket unit can then be inserted.