TM 5-3895-373-207.6.REPAIR/REPLACE OPERATOR CONTROL CONSOLE ASSEMBLY - Continued.C.INSTALL - Continued.14.CONNECT BATTERY CABLES.WARNINGWhen connecting batteries, connectpositive battery cable beforeconnecting negative battery cable.Failure to connect batteries in theproper sequence may lead toelectrical shock or short circuit andresult in personnel injury.a.Reconnect positive battery cable (6) andbattery nut (4) to positive terminal ofinboard battery.b.Reconnect negative battery cable (5) andbattery nut (4) to negative terminal ofoutboard battery.WARNINGElectrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.c.Apply electrical insulating varnish toterminals on batteries.d.Install rubber battery terminal covers (3)onto battery terminals.e.Install battery box covers (2) on bothbatteries and buckle battery box holddownstraps (1).NOTEFOLLOW-ON-TASKS:Close center top left access door per TM 5-3895-373-10.Close center top right access door per TM 5-3895-373-10.Close rear top left access door per TM 5-3895-373-10.Install operator control console protective cover per TM 5-3895-373-10.END OF TASK7-54